64
and alarm outputs for each individual area. These dry contacts may be used to show area status
on an LED display or to allow the system to be monitored by a central/monitoring station using a
digital communicator or other transponder-type device. If the central/monitoring station is
equipped with the EUROPLEX 4100 DVACS
(tm)
receiver, the C-LEMs are unnecessary as all
zone, user, arm/disarm, and diagnostic information will be transmitted to the station.
The following chart summarizes the area number and the associated C-LEM addresses:
AREA ARMED ALARM EXIT BUZZER
121 31 41
222 32 42
323 33 43
424 34 44
525 35 -
626 36 -
727 37 -
828 38 -
COMMON 29 39 -
SYSTEM OUTPUTS common to all areas:
Timed Bell (panel relay) 7
Latched Internal Bell (C-LEM) 10
Dialler/Transponder (panel relay) 1 (fail alarm)
This completes the set-up procedure for an 8-area installation.